TPC Air Particulate Filter Regulator 1/2" NPT Compressed Air Filter UPW4000-04
$ 52.79
- Description
- Size Guide
Description
TPC Pneumatic UPW4000-04* Inlet & Outlet: 1/2" NPT
* Drain Type: Manual Drain
* Max. Pressure: 250 PSI
* Max Operating Pressure: 0-150 PSI: Gauge Included
* Element: 5 Micron
* Compressed Air After Filter: Particle & Moisture Remover
Particulate Filter offers cost effective solution for filtering particulate and moisture in your airline. PPF Series Filters use 5 Micron Element as a standard element and offer 2, 5, 20 & 40 Micron Elements as an option. It also provides bowl options (Metal or Polycarbonate) as well as drain options (Auto or Manual). Modular design allows PPF Series Filters to be connected to PPR Series Regulator and/or PPL Series Lubricator to complete a full Filter Regulator Lubricator (FRL) unit.
Installation
Install units so the airflow is in the direction “IN-OUT” as indicated by arrow on the head of the unit. Install filter/regulator first in line of additional units such as regulators or lubricators, and as close as possible to the pneumatic tools or appliances being serviced.
Filter/Regulator must be installed in vertical, downstream position for proper function.
FILTER: Filtering out of dirt and foreign particles, and the separation of moisture is automatic with air flow. There are no moving parts and no adjustments are necessary. Accumulated sludge and moisture should be drained off. Sediment should not be permitted to fill above the lower baffle. Wash filter element at intervals with methylene chloride or similar cleansing fluid to maintain filtering efficiency. To clean element, depressurize system, pull down the lock and twist off the metal guard and polycarbonate bowl and unscrew element from head. Dry filter element thoroughly before reassembling. Clean filter bowl(s) only with soapy water. Inspect O-ring, replacing if damaged or distorted. Reassemble with care to avoid stripping threads on bowl. After a metal bowl with sight is tightened, it may be rotated up to 180° (for proper viewing.)
Operation & Adjustments
REGULATOR: Before supplying the air, turn the adjusting knob counter-clockwise until compression is released from the control spring.
Turn on the air supply and adjust the knob to set the desired secondary pressure by turning the knob clockwise.
Note:
Adjustment knob must be pulled away from the body of the regulator to operate. After desired secondary pressure is set, pushing the knob back towards the body will lock the control knob.
IMPORTANT: Use care to avoid screwing fittings too far into body of units as it may close internal ports. Normally finger tight plus one turn will seal.